This Kinematic Viscometer is designed and manufactured specially according to the national standard "GB265 – 88 Determination of kinematic viscosity of petroleum products" . It's suitable to determine kinematic viscosity of liquid petroleum products. This apparatus has the function of timing of the trial sample movement and can calculate the final result of kinematic viscosity. This method is suitable to determine kinematic viscosity of liquid petroleum products ( It refers to Newtonian liquids ), and its unit is m2/s. Generally in actual utilization, the unit is mm2/s. The dynamic viscosity is equal with the result which use kinematic viscosity to multiply the density of the liquid. By this method, it can determine the time that the liquid with the certain volume flows past the calibrated glass capillary viscometer under the gravity in the certain stable temperature and the value that the constant value of capillary in the viscometer multiplies the flowing time, that is , the determined kinematic viscosity of liquid at the temperature. At the temperature, the value that kinematic viscosity multiplies the density of the liquid in the same temperature is the dynamic viscosity at the temperature.

נתונים טכניים
חורי אמבטיה נוזליים | 4 |
טווח לשליטה בטמפרטורה | Indoor temperature—120 degree |
דיוק לשליטה בטמפרטורה | Room temperature -120 degree Less than or equal to ±0.1 degree |
טמפרטורת חדר | -40 degree Less than or equal to ±0.2 degree |
מקור כוח קלט | AC220V±10V, 50HZ |
כוח חימום | 1000W |
זמני מבחן | מ 1 עד 6 פעמים, יכול להתאים. |





תנאי שימוש
(1) טמפרטורת הסביבה: 0 מעלות -40 מעלות
(2) לחות יחסית:<>
תשומת לב
(1). כאשר אין מים בתוך האקווריום, זה אוסר על הדלקה.
(2). In the liquid of the bathtub, there can't be impurities and floating materials in order to avoid to block the test holes. For the new bath liquid , it often appears bubbles when heating, which will affect the test, especially when it appears bubbles in the test holes, it will have the most serious affect. Please loose the capillary to check if there is bubble in the test holes. If it appears, please use the hose to blow in order to get rid of the bubbles or use the clean the toothbrush to wash off the bubbles.
(3). לפני שאנו משתמשים במכשיר, עלינו להבטיח הארקה אמינה.
(4). כאשר אנו -מפעילים מחדש את המכשיר, מרווח השימוש צריך להיות מעל 15 דקות. והמכשיר מופעל במצב אמבטיה קרה, ויש להשתמש בו לאחר 45 דקות.
(5). When we rectify the temperature with the full-immersion thermometer, the effective scale of the thermometer can't be exposed to the liquid level of the constant temperature bath.
(6). אסור לאחסן או להשתמש במכשיר בסביבה הרטובה עם הגז המאכל.
(7). כאשר אנו חותכים את הנימים, נא לשים לב לגובה הפתח העליון ולהימנע מכניסה למים במבחנה.
(8). לאחר שימוש למשך תקופה או כאשר אנו מוצאים שמדידת מפלס השמן אינה רגישה, עלינו לנקות את חורי הבדיקה בתפס הבדיקה בזמן.
(9). During using the apparatus, if appears fault, you should invite the professionals to repair and contact with us in time. If it's quality problem, we can offer the gratuitous warranty within one year.
(10). עבור מקור הכוח, עליך לשמור על הארקה טובה.



תגיות פופולריות: HZYN-1301 ASTM D445 צמיג צמיגי שמן אוטומטי, סין, ספקים, יצרנים, מחיר, למכירה, מד ויסקוסימטר קינמטי, מד ויסקומטר קינמטי למוצרי נפט, מד ויסקומטר קינמטי נייד אוטומטי, אמבט ויסקומטר קינמטי, מד ויסקומטר קינמטי עם אמבט דיגיטלי, ISO3104 Viscoil Crude , hzyn-1301, מד צמיגות קינטית, בדיקת צמיגות קינמטית של ביטומן, מד צמיגות קינמטי של שמן בידוד, מד צמיגות קינמטי, בודק צמיגות שמן מנוע