+86-312-6775656
HZ-2009 High Voltage Switch Circuit Breaker Analyzer
video
HZ-2009 High Voltage Switch Circuit Breaker Analyzer

HZ-2009 High Voltage Switch Circuit Breaker Analyzer

High Voltage Switch Circuit Breaker Analyzer Please notice that it's only allowed to work with well trained personnel and with the power systems familiar personnel.
Product Details ofHZ-2009 High Voltage Switch Circuit Breaker Analyzer

 

HZ-2009 High Voltage Switch Timing Test Circuit Breaker Analyzer

circuit breaker analyzer

High Voltage Circuit Breaker Analyzer Precautions

1. Please notice that it's only allowed to work with well trained personnel and with the power systems familiar personnel.

2. The connect action of the test lines should be done before supply power to the instrument.

3. When the instrument is turned on, do not touch the measurement circuit, control output circuit and the conductors connected to it. Before connecting the input or output terminals of the instrument, be sure to ground the instrument reliably.

4. Try to use the special test leads and accessories provided by this instrument.

5. In the case of connecting the DC output line, before turning on the power switch and control switch of the instrument, be sure to confirm that the switch is malfunctioning, so as not to cause any possible personal and equipment hazards.

6. Avoid using it in humid, flammable and explosive environments.

7. The power supply of the instrument is 220V AC, and 380V is prohibited.

High Voltage Circuit Breaker Analyzer

High Voltage Circuit Breaker Analyzer

High Voltage Circuit Breaker Analyzer

High Voltage Circuit Breaker Analyzer

High Voltage Circuit Breaker Analyzer Technical Characteristics

Test channels

12 channels with 25V, the current is 50mA

Transducer

One analog transducer.

TIME

Recording time length

0-20.0s

Time accuracy

±0.l percent reading ± 2 LSB

Resolution

0.1ms

Motion

Range

0-1000mm

Accuracy

±1 percent reading ±1LSB

Resolution

0.1mm

Velocity

Ranges

0.01-20.00m/s

Accuracy

±1 percent reading ±1LSB

Resolution

0.01m/s

DC POWER

Ranges

5-260V

Max current

20A

Accuracy

±1 percent reading ±1LSB

Load change

Less than or equal to 1 percent

TRI&ER

Voltage

5-260V

Current

0.1-20A

Transducer

The transducer states changes

Channels

Channels states changed

DIMENSIONS

415mm320mm168mm

WEIGHT

8kg

OPERATION TEMPERATURE

-10 degree -50 degree

HUMIDITY

Less than or equal to 80 percent RH

POWER SUPPLY

Voltage

AC 220V±10 percent

FREQUENCE

50Hz±10 percent

SAFETY

Insulation resistance

>2MΩ

Leakage current

<3.5mA

Immunity

AC 1500V 50Hz, 1min.

image010

image012

image014

Request for quote_

תגיות פופולריות: HZ-2009 High Voltage Switch Circuit Breaker Analyzer, China, suppliers, manufacturers, price, for sale, circuit breaker analyzer testing equipment, circuit breaker analyzer tester, circuit breaker analyzer hs code 90309090, High Voltage Switching Test System, hz-2009, hz2009, Circuit breaker vibration analyzer, circuit breaker analayser, high voltage circuit breaker analysis system

שלח החקירה

(0/10)

clearall